@@ -0,0 +1,198 @@
|
|
|
+sheet,address,type,name,unit_or_values
|
|
|
+Inverter modbusRTU (ID == 4),20000,RO,The type of machine High,"
|
|
|
+PH/EP/PV"
|
|
|
+Inverter modbusRTU (ID == 4),20001,RO,The type of machine Low,1800/3000
|
|
|
+Inverter modbusRTU (ID == 4),20002,RW,Serial number High,
|
|
|
+Inverter modbusRTU (ID == 4),20003,RW,Serial number Low,
|
|
|
+Inverter modbusRTU (ID == 4),20004,RO,Hardware version,1.00.00
|
|
|
+Inverter modbusRTU (ID == 4),20005,RO,Software version,"1.00.00
|
|
|
+"
|
|
|
+Inverter modbusRTU (ID == 4),20006,RO,Communication Protocal Edition,1.00.00
|
|
|
+Inverter modbusRTU (ID == 4),20009,RW,Battery voltage calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20010,RW,Inverter voltage calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20011,RW,Grid voltage calibration coefficient,"16384
|
|
|
+"
|
|
|
+Inverter modbusRTU (ID == 4),20012,RW,Bus voltage calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20013,RW,Control Current calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20014,RW,Inverter Current calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20015,RW,Grid Current calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20016,RW,Load Current calibration coefficient,16384
|
|
|
+Inverter modbusRTU (ID == 4),20101,RW,Inverter offgrid work enable,0:OFF 1:ON
|
|
|
+Inverter modbusRTU (ID == 4),20102,RW,Inverter output voltage Set,220.0V-240.0V
|
|
|
+Inverter modbusRTU (ID == 4),20103,RW,Inverter output frequency Set,50.00Hz/60.00Hz
|
|
|
+Inverter modbusRTU (ID == 4),20104,RW,Inverter search mode enable,0:OFF 1:ON
|
|
|
+Inverter modbusRTU (ID == 4),20108,RW,Inverter discharger to grid enable,"48V: 0:OFF 1:ON
|
|
|
+
|
|
|
+24V: Null"
|
|
|
+Inverter modbusRTU (ID == 4),20109,RW,Energy use mode,"48V:1:SBU;2:SUB;3:UTI;4:SOL (for PV;PH)
|
|
|
+ 1:BAU; 3:UTI;4:BOU (for EP)
|
|
|
+
|
|
|
+12V 24V:1:SBU;;3:UTI;4:SOL (for PV;PH)
|
|
|
+ 1:BU; 3:UTI (for EP)
|
|
|
+
|
|
|
+"
|
|
|
+Inverter modbusRTU (ID == 4),20111,RW,Grid protect standard,0:VDE4105; 1:UPS ; 2:home ;3:GEN
|
|
|
+Inverter modbusRTU (ID == 4),20112,RW,SolarUse Aim,"0:LBU 1:BLU(defalut)(for PV;PH)
|
|
|
+0:LB 1:LU(defalut) (for EP)"
|
|
|
+Inverter modbusRTU (ID == 4),20113,RW,Inverter max discharger current,"48V: 0.1A(AC)
|
|
|
+12V 24V: Null"
|
|
|
+Inverter modbusRTU (ID == 4),20118,RW,Battery stop discharging voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),20119,RW,Battery stop charging voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),20125,RW,Grid max charger current set,0.1A(DC)
|
|
|
+Inverter modbusRTU (ID == 4),20127,RW,Battery low voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),20128,RW,Battery high voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),20132,RW,Max Combine charger current,0.1A(DC)(for PV;PH)
|
|
|
+Inverter modbusRTU (ID == 4),20142,RW,System setting,
|
|
|
+Inverter modbusRTU (ID == 4),20143,RW,Charger source priority,"0:Soalr first (for PV;PH)
|
|
|
+2:Solar and Utility(default) (for PV;PH)
|
|
|
+3:Only Solar (for PV;PH)
|
|
|
+
|
|
|
+
|
|
|
+2:Utility charger enable (default) (for EP)
|
|
|
+3:Utility charger disable (for EP)
|
|
|
+"
|
|
|
+Inverter modbusRTU (ID == 4),20144,RW,Solar power balance,"0:SBD
|
|
|
+1:SBE"
|
|
|
+Inverter modbusRTU (ID == 4),20213,RW,Remove the accumulated data,0:No remove the accumulated data 1:Remove the accumulated data
|
|
|
+Inverter modbusRTU (ID == 4),20214,RW,Reset the parameter,0:No effect 1:Action
|
|
|
+Inverter modbusRTU (ID == 4),25201,RO,work state,0:PowerOn 1:SelfTest 2:OffGrid 3:Grid-Tie 4:ByPass 5:Stop 6:Grid charging
|
|
|
+Inverter modbusRTU (ID == 4),25202,RO,AC voltage grade,"230:230V
|
|
|
+120:120V"
|
|
|
+Inverter modbusRTU (ID == 4),25203,RO,Rated power(VA),VA
|
|
|
+Inverter modbusRTU (ID == 4),25204,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25205,RO,Battery voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),25206,RO,Inverter voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),25207,RO,Grid voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),25208,RO,BUS voltage,0.1V
|
|
|
+Inverter modbusRTU (ID == 4),25209,RO,Control current,0.1A
|
|
|
+Inverter modbusRTU (ID == 4),25210,RO,Inverter current,0.1A
|
|
|
+Inverter modbusRTU (ID == 4),25211,RO,Grid current,0.1A
|
|
|
+Inverter modbusRTU (ID == 4),25212,RO,Load current,0.1A
|
|
|
+Inverter modbusRTU (ID == 4),25213,RO,PInverter,1W
|
|
|
+Inverter modbusRTU (ID == 4),25214,RO,PGrid,1W
|
|
|
+Inverter modbusRTU (ID == 4),25215,RO,PLoad,1W
|
|
|
+Inverter modbusRTU (ID == 4),25216,RO,Load percent,0.01
|
|
|
+Inverter modbusRTU (ID == 4),25217,RO,SInverter,1VA
|
|
|
+Inverter modbusRTU (ID == 4),25218,RO,SGrid,1VA
|
|
|
+Inverter modbusRTU (ID == 4),25219,RO,Sload,1VA
|
|
|
+Inverter modbusRTU (ID == 4),25220,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25221,RO,Qinverter,1var
|
|
|
+Inverter modbusRTU (ID == 4),25222,RO,Qgrid,1var
|
|
|
+Inverter modbusRTU (ID == 4),25223,RO,Qload,1var
|
|
|
+Inverter modbusRTU (ID == 4),25224,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25225,RO,Inverter frequency,0.01Hz
|
|
|
+Inverter modbusRTU (ID == 4),25226,RO,Grid frequency,0.01Hz
|
|
|
+Inverter modbusRTU (ID == 4),25227,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25228,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25229,RO,Inverter max number,
|
|
|
+Inverter modbusRTU (ID == 4),25230,RO,Combine type,
|
|
|
+Inverter modbusRTU (ID == 4),25231,RO,Inverter number,
|
|
|
+Inverter modbusRTU (ID == 4),25232,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25233,RO,AC radiator temperature,1℃
|
|
|
+Inverter modbusRTU (ID == 4),25234,RO,Transformer temperature,1℃
|
|
|
+Inverter modbusRTU (ID == 4),25235,RO,DC radiator temperature,1℃
|
|
|
+Inverter modbusRTU (ID == 4),25236,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25237,RO,Inverter relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25238,RO,Grid relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25239,RO,Load relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25240,RO,N_Line relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25241,RO,DC relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25242,RO,Earth relay state,0: Disconnect 1:Connect
|
|
|
+Inverter modbusRTU (ID == 4),25243,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25244,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25245,RO,Accumulated charger power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25246,RO,Accumulated charger power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25247,RO,Accumulated discharger power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25248,RO,Accumulated discharger power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25249,RO,Accumulated buy power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25250,RO,Accumulated buy power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25251,RO,Accumulated sell power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25252,RO,Accumulated sell power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25253,RO,Accumulated load power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25254,RO,Accumulated load power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25255,RO,Accumulated self_use power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25256,RO,Accumulated self_use power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25257,RO,Accumulated PV_sell power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25258,RO,Accumulated PV_sell power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25259,RO,Accumulated grid_charger power high,1000KWH
|
|
|
+Inverter modbusRTU (ID == 4),25260,RO,Accumulated grid_charger power low,0.1KWH
|
|
|
+Inverter modbusRTU (ID == 4),25261,RO,Error message 1,
|
|
|
+Inverter modbusRTU (ID == 4),25262,RO,Error message 2,
|
|
|
+Inverter modbusRTU (ID == 4),25263,RO,Error message 3,
|
|
|
+Inverter modbusRTU (ID == 4),25264,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25265,RO,Warning message 1,
|
|
|
+Inverter modbusRTU (ID == 4),25266,RO,Warning message 2,
|
|
|
+Inverter modbusRTU (ID == 4),25267,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25268,RO,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25269,RO,Serial number High,
|
|
|
+Inverter modbusRTU (ID == 4),25270,RO,Serial number Low,
|
|
|
+Inverter modbusRTU (ID == 4),25271,RO,Hardware version,1.00.00
|
|
|
+Inverter modbusRTU (ID == 4),25272,RO,Software version,1.00.00
|
|
|
+Inverter modbusRTU (ID == 4),25273,RO,Batt power,W
|
|
|
+Inverter modbusRTU (ID == 4),25274,RO,Batt current,A
|
|
|
+Inverter modbusRTU (ID == 4),25275,RO,Batt voltage grade,"48:48V 24:24V
|
|
|
+12:12V"
|
|
|
+Inverter modbusRTU (ID == 4),25276,,reserved,
|
|
|
+Inverter modbusRTU (ID == 4),25277,RO,Rated power(W),W
|
|
|
+Inverter modbusRTU (ID == 4),25278,RO,Communication Protocal Edition,1.00.00
|
|
|
+Inverter modbusRTU (ID == 4),25279,RO,Arrow Flag,bit
|
|
|
+PV Charger ModbusRtu (ID == 4),10001,RO,The type of machine,"
|
|
|
+PC1600"
|
|
|
+PV Charger ModbusRtu (ID == 4),10002,WR,Serial number High,
|
|
|
+PV Charger ModbusRtu (ID == 4),10003,WR,Serial number Low,
|
|
|
+PV Charger ModbusRtu (ID == 4),10004,RO,Hardware version,1.0.00
|
|
|
+PV Charger ModbusRtu (ID == 4),10005,RO,Software version,"1.0.00
|
|
|
+"
|
|
|
+PV Charger ModbusRtu (ID == 4),10006,WR,PV voltage calibration coefficient,16384
|
|
|
+PV Charger ModbusRtu (ID == 4),10007,WR,Battery voltage calibration coefficient,16384
|
|
|
+PV Charger ModbusRtu (ID == 4),10008,WR,Charger current calibration coefficient,"16384
|
|
|
+"
|
|
|
+PV Charger ModbusRtu (ID == 4),10103,WR,Float voltage,0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),10104,WR,Absorption voltage,0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),10105,WR,Battery low voltage(for PV;PH),0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),10106,WR,reserved,
|
|
|
+PV Charger ModbusRtu (ID == 4),10107,WR,Battery High voltage(for PV;PH),0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),10108,WR,PV max charger current(for PV;PH),0.1A
|
|
|
+PV Charger ModbusRtu (ID == 4),10110,WR,Battery type,"0:no choose 1:Use defined battery 2:lithium battery
|
|
|
+3:SEALED_LEAD battery
|
|
|
+4:AGM battery
|
|
|
+5:GEL battery
|
|
|
+6:FLOODED battery "
|
|
|
+PV Charger ModbusRtu (ID == 4),10111,WR,Battery AH,1AH
|
|
|
+PV Charger ModbusRtu (ID == 4),10112,WR,Remove the accumulated data,0:No remove the accumulated data 1:Remove the accumulated data
|
|
|
+PV Charger ModbusRtu (ID == 4),10118,WR,Battery equalization enable,0:Disable 1:Enable
|
|
|
+PV Charger ModbusRtu (ID == 4),10119,WR,Battery Equalization voltage,0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),10120,WR,reserved,reserved
|
|
|
+PV Charger ModbusRtu (ID == 4),10121,WR,Battery equalized time,1min
|
|
|
+PV Charger ModbusRtu (ID == 4),10122,WR,Battery Equalized timeout,1min
|
|
|
+PV Charger ModbusRtu (ID == 4),10123,WR,Equalization interval,1day
|
|
|
+PV Charger ModbusRtu (ID == 4),10124,WR,Equalization actived immediately,0:No effect 1:Action
|
|
|
+PV Charger ModbusRtu (ID == 4),15201,RO,Charger workstate,"0:Initialization mode
|
|
|
+1:Selftest Mode
|
|
|
+2: Work Mode
|
|
|
+3:Stop Mode"
|
|
|
+PV Charger ModbusRtu (ID == 4),15202,RO,Mppt state,"0:Stop
|
|
|
+1:MPPT
|
|
|
+2: Current limiting"
|
|
|
+PV Charger ModbusRtu (ID == 4),15203,RO,charging state,"0:Stop
|
|
|
+1:Absorb charge
|
|
|
+2: Float charge
|
|
|
+3:EQ charge"
|
|
|
+PV Charger ModbusRtu (ID == 4),15204,RO,reserved,
|
|
|
+PV Charger ModbusRtu (ID == 4),15205,RO,PV voltage,0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),15206,RO,Battery voltage,0.1V
|
|
|
+PV Charger ModbusRtu (ID == 4),15207,RO,Charger current,0.1A
|
|
|
+PV Charger ModbusRtu (ID == 4),15208,RO,Charger power,1W
|
|
|
+PV Charger ModbusRtu (ID == 4),15209,RO,Radiator temperature,1℃
|
|
|
+PV Charger ModbusRtu (ID == 4),15210,RO,External temperature,1℃
|
|
|
+PV Charger ModbusRtu (ID == 4),15211,RO,Battery Relay,
|
|
|
+PV Charger ModbusRtu (ID == 4),15212,RO,PV Relay,
|
|
|
+PV Charger ModbusRtu (ID == 4),15213,RO,Error message,Refer to frame Charger Error message 1
|
|
|
+PV Charger ModbusRtu (ID == 4),15214,RO,Warning message,Refer to frame Charger Warning message 1
|
|
|
+PV Charger ModbusRtu (ID == 4),15215,RO,BattVol Grade,1V
|
|
|
+PV Charger ModbusRtu (ID == 4),15216,RO,Rated Current,0.1A
|
|
|
+PV Charger ModbusRtu (ID == 4),15217,RO,Accumulated PV power high,1000KWH
|
|
|
+PV Charger ModbusRtu (ID == 4),15218,RO,Accumulated PV power low,0.1KWH
|
|
|
+PV Charger ModbusRtu (ID == 4),15219,RO,Accumulated day,1day
|
|
|
+PV Charger ModbusRtu (ID == 4),15220,RO,Accumulated hour,1hour
|
|
|
+PV Charger ModbusRtu (ID == 4),15221,RO,Accumulated minute,1minute
|